Analysis of the electric
conductivity of the
milk,
-
Early detection
of subclinical mastitis.
-
Systematic monitoring of udder
health especially after calving and before
drying-off,
Return to top of page |

|
|

.gif) |
Fast,
simple measurement of the foremilk sample, using small sample
volume,
|
.gif) |
Exact
values through digital display, no subjective influence by the
milker,
|
.gif) |
No additional chemicals
necessary,
|
.gif) |
Direct
relationship of conductivity value with outset of
infection,
|
.gif) |
Direct
indication of mastitis-suspect quarters,
|
.gif) |
Memory
holds the conductivity values of one udder (four
measurements),
|
.gif) |
Simple
operation thanks to automatic calibration,
|
.gif) |
No
battery replacement necessary, the
Mast O Test V.2 is powered by a lithium battery sufficient to giver 50 000
readings +. |  | Light:
weight: 230 grams | |  | Robust:
Casing injection molded - 2 mm Terluran® (very high impact
resistant) | |
Return to top of page
| Battery voltage: |
3.6 V |
| Minimum number of tests: |
50
000 |
| Test time: |
8
seconds |
| Temperature compensation ;
automatic NTC, range: |
5-45 °C |
| Limit for dirty cell: |
> 1 mS/cm |
| Limit for red LED: |
> 7 mS/cm |
| Range for yellow LED: |
5.4 … 6.9 mS/cm |
| Limit for green LED: |
< 5.3 mS/cm |
| Quarter evaluation: |
> 15 % in relation to the smallest value |
| (only values > 2.5 mS/cm are accepted) |
|
| Measuring range: |
0
-12 mS/cm |
Return to top of page
|